Friday, September 20, 2013

Neuroform Intracranial Stenting for Aneurysms Using Simple and Multi-stent Technique Is Associated With Low Risk of Magnetic Resonance Diffusion-Weighted Imaging Lesions [feedly]


 
 
Shared via feedly // published on Neurosurgery - Current Issue // visit site
Neuroform Intracranial Stenting for Aneurysms Using Simple and Multi-stent Technique Is Associated With Low Risk of Magnetic Resonance Diffusion-Weighted Imaging Lesions
imageBACKGROUND:Detection of procedural thromboembolism by diffusion-weighted magnetic resonance imaging (MR-DWI+) can help identify and mitigate endovascular risk factors. Data remain scant on procedural MR-DWI+ following the use of the Neuroform open-cell design stent in aneurysm embolization. OBJECTIVE:We sought to evaluate the incidence of MR-DWI+ in Neuroform simple and multi-stent construct stenting for intracranial aneurysms in an attempt to delineate baseline risk and identify possible associated procedural factors. METHODS:Seventy-six patients receiving 97 Neuroform stents in the treatment of intracranial aneurysm were identified from a prospective database and eligible for inclusion in the study. Diffusion-weighted magnetic resonance imaging (MR-DWI) was obtained in all patients within 48 hours of the procedure and reviewed for the presence of MR-DWI+ with patient records reviewed for analysis of factors predisposing to these lesions. RESULTS:Patients were treated with single-stent Neuroform constructs in 57 cases (73%) and multi-stent Neuroform constructs in 21 cases (27%). Y-stent technique was used in 16 cases. MR-DWI+ was identified in 7 of 78 cases (9.0%), with MR-DWI+ in 0 of 10 subarachnoid hemorrhage cases. No MR-DWI lesions led to a permanent neurological deficit at discharge. There was no MR-DWI+ in patients treated with Y-stenting or multi-stent Neuroform constructs. The only factor associated with ipsilateral MR-DWI+ was target aneurysm location on an arterial sidewall over bifurcation (P = .01). CONCLUSION:The Neuroform stent carries a very low risk of MR-DWI+ compared with its closed-cell design counterpart. Subarachnoid hemorrhage and deployment of multiple stents in the same anatomical region in configurations such as the Y-stent construct did not increase the risk of acute procedural thromboembolism. ABBREVIATIONS:DWI, diffusion-weighted imagingMR-DWI, diffusion-weighted magnetic resonance imagingMR-DWI+, magnetic resonance diffusion-weighted imaging hyperintense lesionSAH, subarachnoid hemorrhage

No comments:

Post a Comment