Treatment of Blister-Like Aneurysms With the Pipeline Embolization Device

Treatment of Blister-Like Aneurysms With the Pipeline Embolization Device
Neurosurgery - Current Issue

imageBACKGROUND: Endovascular vessel reconstruction with the pipeline embolization device (PED) has become common practice. Data on the safety and efficacy of the PED in blister-like aneurysms (BLAs) are limited. OBJECTIVE: To retrospectively present our experience with use of the PED in BLAs. METHODS: A total of 8 patients harboring 8 BLAs were treated with the PED at our institution between November 2011 and April 2013. RESULTS: Aneurysm size was 2.5 mm on average. Five patients had sustained a subarachnoid hemorrhage (SAH), 1 patient presented with sentinel headaches, and in 2 patients the aneurysm was incidentally discovered. Seven aneurysms arose from the ICA and 1 from the basilar artery. Placement of the PED was successful in all 8 patients. There were no procedural or perioperative complications in any of the patients. At the latest follow-up, all 8 patients achieved a favorable outcome (mRS 0-2). Angiographic follow-up was available for 6 patients at a mean time point of 3.9 months. Follow-up angiography showed 100% aneurysm occlusion in 5 patients and marked decrease in aneurysm size in 1 patient. CONCLUSION: The findings of this study suggest that the PED may be a safe and effective treatment for BLAs. Given the limitations of other treatment modalities and the challenging nature of BLAs, flow diversion may be a valuable option for these lesions.

Original Article: http://journals.lww.com/neurosurgery/Fulltext/2014/05000/Treatment_of_Blister_Like_Aneurysms_With_the.7.aspx