Saturday, March 1, 2014

[Articles] Acute post-stroke blood pressure relative to premorbid levels in intracerebral haemorrhage versus major ischaemic stroke: a population-based study

[Articles] Acute post-stroke blood pressure relative to premorbid levels in intracerebral haemorrhage versus major ischaemic stroke: a population-based study
The Lancet Neurology

Our findings suggest that systolic blood pressure is substantially raised compared with usual premorbid levels after intracerebral haemorrhage, whereas acute-phase systolic blood pressure after major ischaemic stroke is much closer to the accustomed long-term premorbid level, providing a potential explanation for why the risks and benefits of lowering blood pressure acutely after stroke might be expected to differ.

Original Article: http://www.thelancet.com/journals/laneur/article/PIIS1474-4422(14)70031-6/abstract?rss=yes

Can non-invasive electrical stimulation of the brain help patients regain a state of consciousness after a coma?

Can non-invasive electrical stimulation of the brain help patients regain a state of consciousness after a coma?
Neurology News & Neuroscience News from Medical News Today

Researchers have shown that transcranial direct-current stimulation allows patients in a minimally conscious state to recover cognitive and motor skills. This simple, safe and relatively low-cost technique could offer clinicians a new way to help these patients recover, even several years after their coma. However, the positive effects appear to be temporary at this stage of research.

Original Article: http://www.medicalnewstoday.com/releases/273308.php

List Depression as Heart Disease Risk Factor, AHA Panel Says

List Depression as Heart Disease Risk Factor, AHA  Says
Medscape Today- Medscape

Depression should join the ranks of obesity, diabetes, hypertension, and smoking as an official heart disease risk factor, an expert AHA panel says.
Medscape Medical News

Original Article: http://www.medscape.com/viewarticle/821253?src=rss

Use of FLAIR Imaging to Identify Onset Time of Cerebral Ischemia in a Canine Model

Use of FLAIR Imaging to Identify Onset Time of Cerebral Ischemia in a Canine Model
AJNR Blog

Editor's Choice

February 2014

(2 of 3)

After an infarction-inducing procedure, 20 dogs were imaged at 3, 4, 5, 6, and 24 hours with FLAIR and DWI. A mismatch between the 2 sequences (positive DWI and negative FLAIR) was found to reliably predict the time of infarct onset. By 6 hours, 95% of dogs had FLAIR abnormalities and by 24 hours all did. However, at 3 hours only 15% of dogs showed positive FLAIR studies. These results could serve as guidelines to estimate the time of onset of ischemic events.

EIC signature

Abstract

BACKGROUND AND PURPOSE
Stroke is a leading cause of death and disability, and many studies have focused on the evolution of FLAIR imaging in the acute and chronic time window. The purpose of this study was to evaluate the potential efficacy of FLAIR-related techniques in identifying the onset time of cerebral ischemia in a canine embolic stroke model.

MATERIALS AND METHODS
An embolic ischemic model was generated through the use of an autologous clot in 20 beagle dogs. Both FLAIR and DWI were performed at 3 hours, 4 hours, 5 hours, 6 hours, and 24 hours after embolization, respectively. Visual "DWI-FLAIR mismatch" was defined as hyperintense signal detected on DWI but not on FLAIR. The relative signal intensity of FLAIR-positive lesions and the degree of DWI-FLAIR mismatch was calculated as relative FLAIR = relative signal intensity of FLAIR positive lesions, mismatch degree = (100−VFLAIR/VDWI) × 100%.

RESULTS
The ischemic model was successfully established in all animals. FLAIR-positive lesions were seen in 3, 11, 16, 19, and 20 beagle dogs at 5 time points after embolization, respectively. There was significant correlation between the relative FLAIR, degree of DWI-FLAIR mismatch, and the onset time (relative FLAIR: r = +0.42; 95% CI, 0.20–0.60; mismatch degree: r = −0.85; 95% CI, 0.89–0.78). Receiver operating characteristic curves showed that the degree of DWI-FLAIR mismatch could identify the hyperacute ischemic lesions with a sensitivity range from 1.00–0.76; visual DWI-FLAIR mismatch sensitivity ranged from 0.85–0.39, whereas specificity was 0.83–0.95 versus 0.85–1.00.

CONCLUSIONS
The relative FLAIR and DWI-FLAIR mismatch values were useful in predicting the onset time in our canine embolic stroke model. The degree of DWI-FLAIR mismatch proposed in our study could be a good indicator with high sensitivity for identifying the hyperacute ischemic stroke.

Full text

The post Use of FLAIR Imaging to Identify Onset Time of Cerebral Ischemia in a Canine Model appeared first on AJNR Blog.



Original Article: http://www.ajnrblog.org/2014/02/28/use-flair-imaging-identify-onset-time-cerebral-ischemia-canine-model/

Patients with painful facial nerve disorder benefit from nonsurgical Gamma Knife stereotactic radiosurgery

Patients with painful facial nerve disorder benefit from nonsurgical Gamma Knife stereotactic radiosurgery
Neurology News & Neuroscience News from Medical News Today

Research by Beaumont Health System radiation oncologists and neurosurgeons found that symptoms of trigeminal neuralgia, or TN, a nerve disorder causing severe facial pain, were reduced in those treated with Gamma Knife stereotactic radiosurgery. The results were published recently in the journal Clinical Neurology and Neurosurgery.

Original Article: http://www.medicalnewstoday.com/releases/273311.php